HOW TO REPLACE INSERT
HOW TO REPLACE INSERT FOR THE BACK GUARD HOLDER

FOR TECH SUPPORT OR SALE'S CALL 1-772-999-2126

HOW TO REPLACE THE INSERT FOR THE BACK KNIFE GUARD
WITH OUT A PRESS (OLD SCHOOL METHOD )

FIRST YOU NEED TO PURCHASE THE INSERT FROM US
http://www.thetenderizerstore.com/catalog/item/8292377/9384178.htm

THEN YOU WILL NEED A 5/16-18 BOLT MAKE SURE THE HEAD WILL NOT BE LARGER THEN THE INSERT A COUPLE OF WASHERS,5/16-18 NUT AND A 3/4" SOCKET

 

INSTALL THE BOLT THRU THE INSERT PLACE THE SOCKET OVER THE
OLD INSERT WASHERS OVER THE SOCKET NOW THE NUT   

   

 

NOW START TO TIGHTEN DOWN THE NUT AND YOU WILL START TO
SEE THE OLD INSERT COMING OUT IT MAY TAKE A LITTLE PRESSURE
THE OLD INSERT HAS BEEN THEIR A LOOONG TIME.

 

 

IT IS OUT

NOW LETS PUT IN THE NEW ONE

 

SEE HOW WE HAVE REVERESED THE OPERATION
THE BOLT GOES THRU THE TOP OF THE NEW INSERT
THE 3/4' SOCKET IS NOW BEHIND THE INSERT WASHER ONT THE SOCKET NUT ONT THE WASHER TRY AND GET THE INSERT AS STRAIGHT AS YOU CAN THIS NEED TO GO IN STRAIGHT
NOW TIGHTEN UP THE NT PULL IT DOWN AS TIGHT AS IT GOES

AND YOU WILL BE BACK IN BUSINESS

I HOPE THIS HELPS

ED BAUD

 WE HAVE NO AFFILATION WITH HOBART CORP,BERKEL OR BIRO MANUFACTURING CO